« Indications · to the product
Ascra Xpro
Use number: 008219-00/00-005
- Crops
- wheat
- Pests
- brown leaf rust of cereals (Puccinia recondita)
- Area of use
- Outdoors
- Field of activity
- Fungicide
- Application technique
- spraying
- Growth stage
- 30 – 61
- Applications per crop
- –
- Applications per growing season
- 2
- authorised until
- 2028-03-31
Application rates
| Condition | Product rate | Water rate |
|---|---|---|
| 1.5 LH | 100 – 400 LH |
Pre-harvest intervals
| Crop | Pre-harvest interval | Remarks | excluded |
|---|---|---|---|
| wheat | – | The PHI is covered by the conditions of use and/or the vegetation period remaining between the application of the plant protection product and the use of the product (e. g. harvest) or the setting of a PHI in days is not required resp. | – |
Timing of application
- from spring at beginning of infestation and/or when first symptoms become visible
Restrictions
| Code | Text | Crop | Buffer zone |
|---|---|---|---|
| NW605-1 | When applying the product on areas adjacent to surface waters - except only occasionally but including periodically water bearing surface waters - the product must be applied with equipment which is registered in the index of 'Loss Reducing Equipment' of 14 October 1993 ('Bundesanzeiger' [Federal Gazette] No 205, p. 9780) as amended. Depending on the drift reduction classes for the equipment stated below, the following buffer zones must be kept from surface waters. In addition to the minimum buffer zone from surface waters stipulated by state law, the ban on application in or in the immediate vicinity of waters must be observed at all times for drift reduction classes marked with "*". | – | – |
| NW606 | The only case in which the product may be applied without loss reducing equipment is when at least the buffer zone stated below is kept from surface waters - except only occasionally but including periodically water bearing surface waters. Violations may be punished by fines of up to 50 000 Euro. | – | 10 m |
| NW701 | Between treated areas which have an incline of more than 2 % and surface waters - including periodically but excluding occasionally water-bearing surface waters - there must be a buffer zone under complete plant cover. The buffer zone's protective function must not be impaired by the use of implements. It must be at least 10 m wide. This buffer zone is not necessary if: -sufficient catching systems are available for the water and soil transported by run-off, which do not flow into surface water or are not connected with the urban drainage system or -the product is used for conservation or no-tillage methods. | – | – |