Data as of: 2026-08-05 Administration DE EN
Plant Protection Product Search

« Indications · to the product

ALTIVATE 6 WG

Use number: 00B100-00/00-002

Crops
winter soft wheat
Pests
spring oat, ryegrass spec., blackgrass
Area of use
Outdoors
Field of activity
Herbicide
Application technique
spraying
Growth stage
20 – 32
Applications per crop
Applications per growing season
1
authorised until
2033-06-30

Application rates

ConditionProduct rateWater rate
0.25 KH 200 – 400 LH

Pre-harvest intervals

CropPre-harvest intervalRemarksexcluded
winter soft wheat The PHI is covered by the conditions of use and/or the vegetation period remaining between the application of the plant protection product and the use of the product (e. g. harvest) or the setting of a PHI in days is not required resp.

Timing of application

Tank mix partners

ProductAuthorisation no.Application rate
00B071-00 00B071-00
1 LH

Restrictions

Code Text Crop Buffer zone
NW609-2 When applying the product on areas adjacent to surface waters - except only occasionally but including periodically water-bearing surface waters - the product must be applied observing the minimum buffer zone stated below. It is not necessary to observe this buffer zone if the product is applied using equipment which is registered in the index of 'Loss Reducing Equipment' of 10 September 2013 (Federal Gazette AT 23.10.2013 B4) as amended. Irrespective of this, in addition to the minimum buffer zone from surface waters stipulated by state law, the ban on application in or in the immediate vicinity of waters must be observed at all times. Violations may be punished by fines of up to 50 000 EUR. 5 m
WH9161 The instructions for use must include a summary of weeds which can be controlled well, less well and insufficiently by the product, as well as a list of species and/or varieties showing which crops are tolerant of the intended application rate and which are not.
WP710 Damage is possible to replanted dicotyledonous intermediate crops and winter rape.
WP734 Damage is possible to the crop.
NW701 Between treated areas which have an incline of more than 2 % and surface waters - including periodically but excluding occasionally water-bearing surface waters - there must be a buffer zone under complete plant cover. The buffer zone's protective function must not be impaired by the use of implements. It must be at least 10 m wide. This buffer zone is not necessary if: -sufficient catching systems are available for the water and soil transported by run-off, which do not flow into surface water or are not connected with the urban drainage system or -the product is used for conservation or no-tillage methods.